Key Features

Output Power 1200mW
Beam Mode Multi-mode
Stability ±1% RMS
Lifetime 10,000 hrs

Top Applications

🏥
Medical
🔬
Research
🖥️
Projection
🔭
Optical

Fluorescence Applications

FITC
TRITC

Optimal excitation for yellow-orange fluorophores

Pricing Information

Quantity 1-10 $7,850
Quantity 11-50 $5,950
Quantity 51-100 $5,580
OEM Integration Contact Us
Request Quote

Technical Specifications

Optical Specifications

Wavelength 574-580 nm (typ. 577nm)
Output Power 1000-1200 mW (typ. 1200mW)
Power Stability (RMS) ±1% (typ.) after 3 min
Power Stability (pk-pk) ±3% (max) after 3 min
Output Mode CW (Continuous Wave)
Beam Divergence 30 mrad (typ.), 40 mrad max
Beam Waist 300 μm
Beam Diameter 0.5 mm at output
Beam Mode Longitude/Transverse Multi
Polarization Ratio 100:1 (Linear)
Residual IR < 3%

Electrical & Environmental

Power Type ACC
LD Voltage 1.8-2.3 VDC (typ. 2V)
LD Current 10A (typ.) at 2V
Power Consumption 20 W (typ.), 27.6W max
Laser Class Class 4
Operating Temp 15-35°C (T±1°C)
Storage Temp 0-40°C
Humidity 5-85% RH
Head Dimensions 19 × 18 × 58 mm
Head Weight 200 g max
Housing Material Brass with gold-plating
Wire Length 200mm (±50mm)
Wire Type 18AWG/28AWG
RoHS Compliant Yes

Performance Characteristics

Warm-up Time < 3 minutes for stability
MTTF (Mean Time To Failure) 10,000 hours @ 25°C
Thermistor Resistance 10.0KΩ @ 25°C, 8.2KΩ @ 30°C, 6.6KΩ @ 35°C
Beam Alignment Tolerance Position: ≤0.5mm, Off-axis: 35mrad typ, 60mrad max

Applications

🏥

Laser Medical Treatment

Photocoagulation therapy, retinal treatments, dermatological procedures, and vascular lesion treatment utilizing yellow wavelength absorption characteristics.

🔬

Scientific Experiment

High-power fluorescence excitation, Raman spectroscopy, photochemistry research, and optical experiments requiring intense 577nm illumination.

🖥️

Laser Projector

High-brightness cinema projection, laser TV systems, large-venue displays, and planetarium installations requiring pure yellow component.

🔭

Optical Instrument

Interferometry, holographic recording, optical pumping applications, and precision measurement systems utilizing yellow laser source.

🧬

Flow Cytometry

Cell sorting and analysis with powerful excitation of yellow-orange fluorescent proteins and dyes in multi-parameter systems.

🎨

Material Processing

Selective material ablation, photopolymerization, and surface treatment applications leveraging 577nm wavelength absorption.

Compatible Fluorophores

The 577nm wavelength provides optimal excitation for yellow-orange fluorophores:

  • TRITC (Em: 580nm)
  • Rhodamine (Em: 590nm)
  • Alexa Fluor 568
  • mOrange (Em: 562nm)
  • Cy3 (Em: 570nm)
  • DyLight 594
  • Texas Red (Em: 615nm)
  • mKusabira Orange
  • Atto 565 (Em: 592nm)

Customer Success

"The Y577D1000-19x18x58-40 laser has transformed our dermatology practice. The compact design provides excellent integration flexibility, while the 1200mW power output enables efficient vascular treatments. The power stability has been exceptional throughout extended procedures, and the gold-plated brass housing ensures reliable long-term operation."

- Dr. Sarah Chen, Laser Dermatology Center, Stanford Medical Institute

Features & Technology

Core Features

  • DPSS laser technology
  • 577nm yellow wavelength output
  • 1000-1200mW output power capability
  • Compact design (19x18x58mm)
  • Continuous wave (CW) operation
  • Excellent power stability ±1% RMS
  • Gold-plated brass housing
  • Multi-mode beam profile
  • Linear polarization 100:1
  • Low power consumption (20W typ)
  • Class 4 laser safety rating
  • ACC power type operation
  • Integrated thermistor monitoring
  • 10,000 hour operational lifetime

Medical Advantages

  • Optimal hemoglobin absorption
  • Excellent melanin interaction
  • Minimal water absorption
  • Precise tissue targeting
  • Stable output for procedures
  • Compact for system integration

Research Benefits

  • High power for strong signals
  • Excellent stability ±1% RMS
  • Multi-mode beam profile
  • Low IR contamination <3%
  • Compact form factor
  • Long operational lifetime

Laser Technology

The Y577D1000-19x18x58-40 utilizes advanced DPSS (Diode-Pumped Solid-State) laser technology to deliver stable, high-power 577nm yellow output. This wavelength is particularly valuable in medical and scientific applications due to its unique absorption characteristics in biological tissues and fluorescent materials.

The compact design with gold-plated brass housing ensures excellent thermal management and long-term reliability. The 1200mW typical power output provides sufficient intensity for demanding applications while maintaining exceptional stability. The multi-mode beam profile offers uniform illumination ideal for medical treatments and fluorescence excitation.

⚠️ Safety Information

Class 4 laser product. Direct exposure to beam is hazardous to eyes and skin. Use appropriate laser safety eyewear (OD 5+ @ 577nm). Follow all safety protocols per IEC 60825-1 and 21 CFR 1040.10. Ensure proper beam containment and interlock systems. The high power output requires special safety precautions.

Resources & Integration

💿 Software & Drivers

Available upon request.

🔧 Technical Resources

Available upon request.

System Integration

Mechanical Interface
  • Compact laser head 19×18×58mm
  • Gold-plated brass housing
  • Direct beam output design
  • 200g maximum weight
  • Mounting holes for integration
Electrical Interface
  • ACC power type
  • 1.8-2.3VDC LD voltage
  • 20W typical power consumption
  • 18AWG/28AWG wire connections
  • Integrated thermistor monitoring