Low noise 638nm laser delivering superior stability for flow cytometry, hematology analysis, and DNA sequencing applications
Quantity 1-10 | $1,290 |
Quantity 11-50 | $1,080 |
Quantity 51-100 | $850 |
OEM Integration | Contact Us |
Wavelength | 635-641 nm (typ 638) |
Output Power | 0-50 mW (CW) |
Power Stability | < 1% RMS / 8 hrs |
Noise (RMS) | < 0.1% (10Hz-2MHz) |
Beam Quality (M²) | < 1.3 |
Beam Diameter | 4.1 × 2.0 mm @ 300mm |
Beam Divergence | 0.3 × 0.5 mrad |
Polarization | Linear, > 20 dB |
Bandwidth | < 2 nm |
Operating Voltage | 12 VDC |
Operating Current | < 2 A |
Power Type | APC |
Control Interface | Master Computer Control |
Operating Temp | 15-40°C |
Storage Temp | -20 to 60°C |
Humidity | 10-90% RH |
Dimensions | 70 × 40 × 45 mm |
Weight | < 200 g |
Beam Height from Base | 19 mm |
Beam Alignment Off-axis | < 2.5 mrad |
Beam Pointing Stability | < 5 μrad/°C |
Polarization Orientation | Vertical ±3° |
Warm-up Time | < 2 minutes |
Output Power Mode | CW |
Housing Material | Grey Anodized Aluminum |
MTTF | 5,000-10,000 hours @ 25°C |
Cell sorting, immunophenotyping, and particle analysis with excellent fluorophore excitation for red-excitable dyes.
Blood cell counting, differentiation, and morphology analysis with superior signal-to-noise ratio for clinical diagnostics.
Next-generation sequencing platforms utilizing red fluorophores, enabling high-throughput genomic analysis and detection.
Wafer inspection, defect detection, and photolithography alignment with exceptional beam stability and low noise.
Excitation of red-shifted fluorophores like Cy5, Alexa Fluor 647, and mCherry in confocal and wide-field microscopy systems.
Chemical identification and material characterization with reduced fluorescence interference in biological samples.
< 0.1% RMS noise enables precise detection in sensitive applications
"A leading medical diagnostics company integrated our R638D050 modules into their hematology analyzers, achieving 30% improvement in cell differentiation accuracy and reducing maintenance intervals by 50% compared to traditional gas lasers. The exceptional low noise performance enabled detection of rare cell populations."
- Dr. Sarah Chen, Director of Engineering, BioAnalytical Systems
The R638D050 utilizes advanced semiconductor laser technology optimized for bioanalytical applications. The 638nm wavelength is specifically chosen for optimal excitation of red fluorophores while minimizing autofluorescence from biological samples, making it ideal for life science instrumentation.
Our proprietary low-noise driver circuit and automatic power control system ensure exceptional stability over extended periods, critical for quantitative measurements in flow cytometry and hematology analysis. The compact design allows easy integration into existing optical systems.
Class 3B laser product. Avoid direct eye exposure. Use appropriate laser safety eyewear (OD 3+ @ 638nm). Follow all safety protocols per IEC 60825-1 and 21 CFR 1040.10.
Available upon request.
Available upon request.
Comprehensive OEM support including custom communication protocols, specialized mounting configurations, and tailored power specifications. Our engineering team provides integration assistance for flow cytometry, hematology, and semiconductor inspection equipment manufacturers.